What is the ASTM A192 Standard?

Jan 07, 2025 Leave a message

ASTM A192 is the ASTM standard specification for minimum-wall seamless carbon steel boiler and superheater tubes for high-pressure service. Tubing usually furnished to the specification runs from 1/2 in to 7 in outside diameter (12.7 to 177.8 mm) with 0.085 in to 1.000 in (2.2 to 25.4 mm) minimum wall. The specification fixes a single low-carbon analysis, delivers tube on a minimum-wall basis, and backs the product with a test regime of tension, flattening, flaring, hardness and hydrostatic or nondestructive electric examination. General requirements follow ASTM A450/A450M, and either inch-pound or SI units may be used, but the two systems are not exact equivalents and must be applied independently of each other. This page gathers the scope, chemistry, mechanical properties, heat treatment rule and inspection requirements in table form so the specification can be checked at a glance.

Scope: what the standard covers

A192 is written for the pressure-carrying tubes of high-pressure boilers and superheaters, the heating surfaces that contain water and steam at temperature. The dimensional range in the table is the range usually furnished to the specification; tubes of other sizes may be supplied provided they comply with every other requirement of the standard. Mechanical property requirements do not apply to tube smaller than 1/8 in (3.2 mm) inside diameter or 0.015 in (0.4 mm) in thickness, which matters mainly for small-bore and instrument applications. For current availability and mill options, see the ASTM A192 pipe product page.

Item ASTM A192 position
Product Minimum-wall seamless carbon steel boiler and superheater tubes for high-pressure service
Outside diameter usually furnished 1/2 in to 7 in (12.7 to 177.8 mm)
Minimum wall usually furnished 0.085 in to 1.000 in (2.2 to 25.4 mm)
Other dimensions Permitted if all other requirements of the specification are met
General requirements ASTM A450/A450M
Units Inch-pound or SI, applied independently; inch-pound governs unless the M designation is ordered

Chemical composition

The analysis is a deliberate low-carbon, manganese-balanced composition. Low carbon keeps the steel easy to weld, bend, expand and flare when tubes are fabricated into boiler panels, while manganese carries a share of the strength. Silicon supports deoxidation in killed-steel practice, and phosphorus and sulfur are limited to 0.035 percent each. The heat analysis on the mill test certificate is the figure to check against the table.

Element, heat analysis Requirement, %
Carbon 0.06 to 0.18
Silicon 0.25 max
Manganese 0.27 to 0.63
Phosphorus 0.035 max
Sulfur 0.035 max

Mechanical properties and hardness caps

Tensile requirements are modest by design. The specification prioritizes ductility and formability so tubes can be bent, expanded and welded into boiler panels without cracking, and the minimum elongation of 35 percent in a 2 in or 50 mm gage length reflects that priority. Hardness is capped rather than given as a range, and the cap depends on wall thickness: heavier walls are tested on the Brinell scale while thinner tube is tested on the Rockwell B scale. Both caps indicate a soft, workable condition rather than a hardened one.

Property Requirement
Tensile strength, min 325 MPa (47 ksi)
Yield strength, min 180 MPa (26 ksi)
Elongation in 2 in or 50 mm, min 35 percent
Hardness, wall 0.200 in (5.1 mm) and over 137 HB max
Hardness, wall under 0.200 in (5.1 mm) 77 HRB max

Reading the figures together gives a practical picture. A tube with 35 percent minimum elongation and a hardness cap will absorb the bending, expanding and welding done in the boiler shop without cracking, while the 325 MPa tensile floor gives the boiler designer the strength basis for the wall calculation. When comparing offers, check that the certificate shows both the tension results and the hardness reading, because a certificate that omits hardness leaves the delivered condition of the tube unverified.

Manufacture and heat treatment

Tubes are made by a seamless process and finished either hot or cold as the order states. The heat treatment rule is simple and is one of the most frequently checked clauses in the standard: hot-finished tube needs no heat treatment, while cold-worked tube must be heat treated at 1200 degrees F (650 degrees C) or higher after the final cold pass. That treatment relieves the stresses introduced by cold drawing and leaves the tube in a condition suited to bending, expanding and welding at the boiler shop. The rule is identical in the ASME adoption of the specification, so one treatment plan covers both designations.

Route Heat treatment requirement
Hot-finished None required
Cold-finished (cold-worked) Heat treated at 1200 degrees F (650 degrees C) or higher after the final cold pass
Purpose of the cold-route treatment Stress relief after cold drawing
Delivery basis Minimum wall

Testing and inspection

Each lot is checked by tension, flattening and flaring tests, with hardness tested against the wall-thickness caps above. Every tube then passes a hydrostatic pressure test, or a nondestructive electric test of the type specified in the order, so that no length leaves the mill unproven for pressure tightness. These are the tests a buyer should expect to see referenced on the certificate, together with the heat analysis. The boiler-tube range on our seamless boiler pipe pages lists supply options that follow this same regime.

Test Basis
Tension test 325 MPa min tensile, 180 MPa min yield, 35 percent min elongation
Flattening test Required, checks soundness of the tube wall
Flaring test Required, checks expansion behavior at the tube end
Hardness test 137 HB max or 77 HRB max by wall thickness
Hydrostatic or nondestructive electric test Each tube

When reviewing the paperwork, match the heat number on the certificate to the tube markings, confirm that the unit system used for acceptance matches the one stated on the order, and keep the certificate with the boiler records so a later replacement order can reference the same requirements without rechecking the analysis.

Need ASTM A192 boiler tube quoted to this specification?

Send the outside diameter, minimum wall, manufacturing condition and quantity, and we will confirm price, mill test certificates and delivery time. Request a quotation.

Frequently Asked Questions

What is ASTM A192 used for?

It covers minimum-wall seamless carbon steel boiler and superheater tubes for high-pressure service, typically the water walls, economizers, superheaters and reheaters of high-pressure boilers.

What sizes are usually furnished to A192?

Outside diameters from 1/2 in to 7 in (12.7 to 177.8 mm) with minimum wall from 0.085 in to 1.000 in (2.2 to 25.4 mm). Tubes of other dimensions may be supplied if every other requirement of the specification is met, so unusual sizes should be confirmed with the mill before ordering.

What is the chemical composition of A192?

Carbon is limited to 0.06 to 0.18 percent, manganese to 0.27 to 0.63 percent, silicon to 0.25 percent max, and phosphorus and sulfur to 0.035 percent max each. The heat analysis on the mill test certificate is the figure checked against these limits.

What are the tensile requirements?

Minimum tensile strength is 325 MPa (47 ksi), minimum yield strength is 180 MPa (26 ksi) and minimum elongation is 35 percent in a 2 in or 50 mm gage length.

Does cold-finished A192 tube need heat treatment?

Yes. Cold-worked tube is heat treated at 1200 degrees F (650 degrees C) or higher after the final cold pass to relieve stress. Hot-finished tube requires no heat treatment.

How is each tube proven for pressure?

Every tube is hydrostatically tested or given a nondestructive electric test such as eddy current examination, as the order specifies, in addition to the tension, flattening, flaring and hardness tests applied to the lot.

A192 Boilers And Pressure Vessel Tubes
A192 High-Pressure Carbon Steel Boiler Tube
A192 superheater tubes